Install Date: Feb 2003
Condition: Installed new and never put into use. As new.
Web Links:
- Manufacturer web site:
www.controlscreening.com
- Spec Sheet:
www.controlscreening.com
S/N: 030203P2 Controller S/N: 020725P5124
XRM: 2003-004 Component 103
Dynavision 615397 System 150150
Overall Dimensions: 285” L x 109” W x 80” H
Inspection Capabilities
Tunnel Size: 59” wide (150 cm): 59” or 150 cm high.
Material Penetration: 27-29 mm steel
Contrast Sensitivity: 2 million + color tones.
Resolution: 38-40 AWG wire
Conveyor: Height: approx. 10.5” off floor.
Speed: Variable, up to 3 m per second. Reversible.
Pulling Weight: Approx. 2,700 lbs
Film Safety: high-speed films up to ISO 1600
Full Auto Sensing without photosensors
X-ray Generator
X-ray tube head: Self-contained, shielded tank
High voltage rating: 160 kV, 140 kV Operating Voltage
Duty cycle: 100% with sealed oil bath cooling.
Beam orientation: Diagonal from side.
Dose rate per exam: 0.1 mR. Lower doses available.
X-ray Detectors
Surface-mounted, multilayer, fully integrated, high frequency, solid
state detectors using high-speed processors and
advanced Pentium 4 signal processing with Multi-Energy. |
Standard with color 17” SVGA monitor. High
resolution, flicker-free, .21 dot pitch, low rad. monitor, 1280 x 1024
video
card. Multi-Energy color included
Features
• Multi-Energy organic and • Auto Outline • High/Low Density &
Stripping
inorganic color & stripping • Auto Scale • High density
• Real Clear • Auto Cal • Help
• Auto Densalert • Dark & Light enhance • Fast (25 second) initial
warm-up
• Auto Track • DensityScan • Fully functional, robust, low profile
• Auto Sense • Color; Reverse B/W • Reversible conveyor direction
Options
• Roller bed or conveyor extensions
Construction:
- Detachable electronics and generator module.
- Brushed stainless steel with steel frame
Environmental Temperature range: 32°- 104°F,
Conditions: 0°- 40°C • Humidity 20% - 95%,
Electrical Power Consumption: <2.5 KVA,
Requirements: 3 phase 208, 380, 415, or 480 volts AC ± 10%,
Weight: 3100 lbs 1406 kg
Installation and Training:
- Unit must be set-up by factory technician.
- Operator must be trained by factory technician
- Cost for set up and training will vary depending upon location. |